NOTIFICATION SETTINGS

 

This tab page allows you to define for which alarms or warnings you want to receive a beep and/or a pop-up. The grids give you an overview of the current configuration. Click on the Select button to modify the configuration.

 

 

Vehicle alarms

Activity takes too long, start driving without activation

Alarm when:

  • the activity takes too long

  • the driver started driving without activating his OBC

Anomaly alarm

Alarm when an anomaly occurs in the Planning module.

Corridor alarm

Alarm when the driver leaves the Corridor. This alarm is created at the back office.

Corridor Fencing alarm

Alarm coming from the OBC, when the driver is not following his secure route.

Deadline read confirmation exceeded

Alarm when the driver has not read the message within the deadline that you have configured in the "Send Message" screen.

Driver confirmation alarm

Alarm when the system was:

  • started / stopped manually (via IS)

  • started / stopped via a message (system message)

  • started via configuration settings

  • stopped due to a time-out

Alarm when:

  • the button was pressed, so system confirmed

  • the button was not pressed within the time foreseen

Driver unknown for OBC

Alarm when the logged on driver is not recognised in the back office.

Driving times alarm

Alarm when:

  • Started driving after 8h of rest

  • Total driving time: x hrs x min

  • Continuous driving time: x hrs x min

  • Continuous rest: x hrs x min

  • Continuous availability: x hrs x min

  • Continuous work: x hrs x min

  • Started driving after x hrs x min of rest

EVL alarm

An alarm sent when the power supply to the on-board computer is interrupted, and EVL (Emergency Vehicle Location) is active.

External devices alarm

An alarm triggered by an external device.

Fuel decrease alarm

The criteria set in the  "Fuel decrease alarm" tab page under "Profiles > OBC profiles" are reached.

GeoFencing alarm

  • Standard: entering / leaving the Geozone

  • ETA: vehicle is too late

  • Restrictive: activity duration exceeded

 

 

 

 

Multiple driver login

Alarm when a driver is logged in on several vehicles at the same time.

Next stop alarm

Alarm when the driver will be arriving too late at the next stop.

OBC activated without TX-MAX key or smart card

Alarm when the OBC is activated without TX-MAX key or smart card.

Planning activity takes too long

Alarm when a specific planning item takes too long.

PTO status alarm

There is a change in the power take-off status or it takes too long. These criteria can be set in the "PTO status alarm" tab page under "Profiles > OBC profiles".

Remote tacho download alarm

The authentication of the RTD has failed.

Service times exceeded

The daily / weekly / monthly / variable service times or the quota amplitude are exceeded.

SOS alarm

A button on the OBC that, when pressed, gives an alarm and sends the GPS coordinates of the vehicle to the home base.

Temperature alarm

The temperature in the cooling unit is higher or lower than the set temperature.

Theft alarm

The alarm is on and pulses are coming through, meaning that the vehicle is moving. The alarm can be deactivated with the "Alarm deactivation password" that is shown on the "Identification" tab page under "Management > Drivers".

 

System alarms

Calibration speed pulse alarm

An alarm indicating that the calibration number of the OBC has been changed. This can be a manual change on the OBC or a change in the source used for the calibration.

Change driver name not successful

Alarm that indicates that the task "Changing driver name on smartcard" could not be executed. The task will be active during 48 hours in the OBC, if the driver whose name you want to change, doesn’t insert his card in the OBC during this period, the command will be deleted.

Date / Time changed

The date or time on the OBC was changed (manually or by a reset).

Invalid licence

Alarm when the navigation licence is no longer valid.

New blocked vehicle

When adjustable parameters are exceeded, the vehicle ends up on a blocked list.

No vehicle found for GSM number

Alarm when the vehicle corresponding with the GSM number is not recognized in the back office.

OBC not on GPRS

An alarm indicating that the on-board computer is no longer transferring information via the GPRS network. It will be sent to the home base when 10 successive messages have been sent via SMS.

Quattro parameters lost

An alarm indicating that the Quattro parameters are lost. This can happen if the driver's card is still in the OBC when charging the Image.

Smart card is 90% full

This alarm informs the dispatcher that he needs to remind the driver to read out his card.

TCG down

The Transics Communication Gateway is not responding.

TCS connection down

Some TCS connections are not responding.

Too much GPRS traffic on OBC

Warning when the Quattro makes too many GPRS connections.

Wrong OBC time

An alarm indicating that the date / time of the on-board computer is too much in the past or in the future.

 

Other warnings

Text messages

An alarm indicating that a new text message (to a dispatcher group) has arrived.

Outdated OBCs